05/18/2024
4:54 PM


 
Permit No. B2402-049 Permit Type   NEWSFR Site Address   6770 W WINDING KNOLL PL
MARANA, AZ 85658
Applied   02/07/2024 Applicant   Lennar Arizona Construction
Approved   02/13/2024 Owner   Lennar Arizona Construction
Issued   02/13/2024 Contractor   Lennar Arizona Construction
Parent Permit No.   M2212-006 Description   SFR MODEL M2212-006 (6081) ELEV B
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/14/2024U/G PLUMBINGDAVID WILLETTAPPROVEDeTRAKiT Inspection Request3/13/2024 9:44:54 AM 3/13/2024 9:44 AM Lennar Arizona Construction Contact Name: Lennar Arizona Construction Site Address: 6770 W WINDING KNOLL PL Phone: 5203088038 e-Mail: [email protected] 3/14/2024 10:15:06 AM OK to cover DWV-HCS. Tracer wire in place.
Ok to cover main water line. Tracer wire in place and under working meter pressure

 03/27/2024PRE-SLABDAVID WILLETTAPPROVEDeTRAKiT Inspection Request3/26/2024 8:21:13 AM 3/26/2024 8:21 AM Lennar Arizona Construction Contact Name: Lennar Arizona Construction Site Address: 6770 W WINDING KNOLL PL Phone: 5203088038 e-Mail: [email protected] 3/27/2024 10:43:49 AM Ok to pour.
Special inspection report onsite.
Ufer rebar in place.
Non-metallic conduit installed for electrical run to Kitchen Island

 03/27/2024U/G PLUMBINGDAVID WILLETTCANCELEDeTRAKiT Inspection Request3/26/2024 8:21:13 AM 3/26/2024 8:21 AM Lennar Arizona Construction Contact Name: Lennar Arizona Construction Site Address: 6770 W WINDING KNOLL PL Phone: 5203088038 e-Mail: [email protected] 3/27/2024 10:42:52 AM Inspection type scheduled in error.

 04/18/2024FRAMING/ROOF NAILINGDAVID WILLETTNOT APPROVEDeTRAKiT Inspection Request4/16/2024 1:29:55 PM 4/16/2024 1:29 PM Lennar Arizona Construction Contact Name: Lennar Arizona Construction Site Address: 6770 W WINDING KNOLL PL Phone: 5203088038 e-Mail: [email protected] 4/18/2024 10:35:56 AM Corrections;
1) Missing shear nailing at several areas; Kitchen, Next Gen, etc...
2) Missing Anchor bolts at Shearwall #1 at Living room.
3) Missing all truss bracing.
4) Missing 3rd king stud at rear SGD per S3.3
5) Missing anchor bolts at Kitchen shearwall at 32" o.c
6) Firestop soffit at west side of rear patio to dining rm.

 04/23/2024FRAMING/ROOF NAILINGDAVID WILLETTNOT APPROVEDeTRAKiT Inspection Request4/22/2024 9:28:15 AM 4/22/2024 9:28 AM Lennar Arizona Construction Contact Name: Lennar Arizona Construction Site Address: 6770 W WINDING KNOLL PL Phone: 5203088038 e-Mail: [email protected] 4/23/2024 10:46:11 AM Corrections;
1) Item # 1 not complete. Walls marked in red
2) Item # 3 not complete. Truss A10M marked on floor in red web #15 and 5 missing bracing.


4/18/2024 10:35:56 AM
Corrections;
1) Missing shear nailing at several areas; Kitchen, Next Gen, etc...
2) Missing Anchor bolts at Shearwall #1 at Living room.
3) Missing all truss bracing.
4) Missing 3rd king stud at rear SGD per S3.3
5) Missing anchor bolts at Kitchen shearwall at 32" o.c
6) Firestop soffit at west side of rear patio to dining rm.

 04/25/2024FRAMING/ROOF NAILINGDAVID WILLETTAPPROVEDeTRAKiT Inspection Request4/24/2024 9:06:44 AM 4/24/2024 9:06 AM Lennar Arizona Construction Contact Name: Lennar Arizona Construction Site Address: 6770 W WINDING KNOLL PL Phone: 5203088038 e-Mail: [email protected] 4/25/2024 10:06:16 AM OK to proceed.
Items from previous inspection corrected.

 04/29/2024ELEC MTR-NEW SERVICE ECOJIM PATTERSONAPPROVEDeTRAKiT Inspection Request4/26/2024 2:21:33 PM 4/26/2024 2:21 PM Lennar Arizona Construction Contact Name: Lennar Arizona Construction Site Address: 6770 W WINDING KNOLL PL Phone: 5203088038 e-Mail: [email protected]